Transport Ventilators

Basic Info

Model No.: S1100

Product Description

 

Transport Ventilators

 

 

I. Intended Usage and Distinct Features Of S1100 Ventilator

Intended Usage:

This series are electrically controlled and pneumatically driver ventilator which can Monitor and display patient’s breathing parameters. It is intended to treat respiratory failure and respiratory insufficiency for pediatric and adult patients. It could be used in ICU, Surgical operation room, Ordinary wards for different types of hospitals.

 

Distinct Features:

Friendly User Interface

*Colorful TFT LCD display screen

*Combined Operation of button and shuttle key, make operation more convenient

*Compact interface design, show the parameters clearly

*Air compressor running stable, low noise, create quiet work environment for doctors.

 

Engineering Medical, power function

*Electric control and pneumatical driven, Applicable to both adults and children

*Multiple working mode and ventilation modes such as IPPV,A/C,PCV,SIMV,SPONT/CPAP,PSV ,SIGH,MAUN

*With air and oxygen mixer of high accuracy, stable and reliable.

*Intelligent Electric PEEP control

*High Integration gas circuit design, decrease the system leakage, system stop and compliance compensation loses.

*Compatible with air compressor

 

Monitoring function, safe and powerful

* Rich parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects, provide complete evidence for treating program making and treatment effect evaluation.

* Real time Flow-time, Pressure-time, Pressure volume loop graphics let users patient conditions clearly and everything in control.

 

Intelligent design, safe and reliable

* Three level alarming system, visual and sound alarm information

* With lots of alarming functions

* With built-in spare power source, when outside power source goes off, back up power source starts to work

* Self-check before running, eliminate system mistake; Separate design of electric and gas, keep safety running of ventilator.

 

Work Condition and Main Technical Parameters

 

Work condition:

 

Gas source:O2

 

Air compressor

 

Rated working pressure:280kpa~600kpa

 

Power source: Voltage ~220V±22V

 

             Frequency:50HZ±1HZ

 

 

 

Main parameters

 

Adjusting range of parameters:

 

Frequency:1 bpm ~ 100 bpm(

 

           SIMV mode:1 bpm~ 40 bpm

 

           Other modes: Adult4 bpm~ 40 bpm Children:20bpm~ 100 bpm

 

Tinsp(inspiratory time):0s~ 12s(Except for SIMV mode Respiratory ratio::4:1~1:8)

 

VT(Tidal volume) range: 0 mL ~ 2000 mL                       

 

                       Adult:25mL ~ 2000 mL Children: 0 mL ~300 mL

 

PEEP: 0 cmH2O ~ 40 cmH2O 

 

CPAP: 0 cmH2O ~ 20 cmH2O

 

Continuous air flow : Adult: L/min ~ 60 L/min  

 

                   Children:2 L/min ~ 30 L/min

 

PTr(Pressure trigger):- 20cmH2O ~ 20 cmH2O

 

FTr:(Flow trigger)0.5 L/min ~ 30 L/min

 

Pc(Pressure control):5cmH2O ~ 80 cmH2O

 

Ps(Pressure support): 0 cmH2O ~ 80 cmH2O

 

Adjusting range of O2 concentration: 21 %~100 %

 

Holding time(Inhalation platform /TIP):      0 ~ 6s(50 % inspiratory time)

 

SIGH adjusting range:1/100 ~ 5/100

 

Suffocation ventilation: OFF,5 s ~ 60 s

 

Pressure limit range:20cmH2O ~ 100 cmH2O

 

Max safety pressure<12.5Kpa

 

 

 

Monitoring parameters:

 

Frequency:0 /min ~ 100 /min

 

VT(Tidal volume):0 mL ~ 2500 mL

 

MV(Tidal volume/min):0 L/min ~ 99 L/min

 

Tube pressure:0 cmH2O ~ 100 cmH2O  

 

Concentration of inhaled oxygen:15 % ~ 100 %

 

 

 

Graphical display

Tube pressure-time wave line    

Air flow-time wave line

 

Pressure volume loop

 

 

 

Alarming and protection function:

 

Alarm when AC power off

 

Alarm when spare power voltage getting low

 

Alarm when theres no9 tidal volume

 

Alarm when ventilation volume too high or too low

 

Alarm when tube pressure too high or too low

 

Pressure limits

 

Alarm when concentration of Oxygen too high or too low

 

Alarm when suffocation occurs

 

Pressure safety relief valve<125cmH2O